Standalone Temperature Data Logger

Stackable fast, accurate and reliable Temperature DAQ's

The K-TC modules belong to the Influx K-series instrumentation range for CAN applications. The stackable K-TC is an ideal for those applications that require a large number of thermocouples for example vehicle durability, winter and summer testing.

​

The K-TC modules CAN Bus settings, calibration and sampling rates are all easily configurable and stored in the K-TC module even when not powered.

​

The K-TC modules have the ability to function as a standalone temperature logger with an inbuilt Micro SDHC storage and the data will be logged with a real timestamp using the internal RTC. 

​

The input calibration and set-up of the K-TC module is easily configurable via Influx K-Cal software, a freely distributable Windows pc application.

CANoutput_Square.png

CAN Output

Micro SD_Square.png

SD Card Storage

Temperature.png

Temperature

Anchor 1
Key Features
Advantages
Package Includes

Key Features:

â–  8 thermocouple connections at 20Hz sampling rate.

â–  Configuration and programming via CAN or USB interface.

â–  Simple signal configuration using a DBC file.

â–  Supplied with configuration software’s Influx K-Cal (Configuration) and TCLogger (Datalogging) for Windows. 

â–  Device drivers available for Windows® applications (32/64-bit).

â–  WakeOnCAN enables K-TC modules to power up and power down in deep sleep mode.

â–  Measurement accuracy: +/- 1 degree C, Measurement resolution: 0.1 degree C.

â–  Supports K, J and T type thermocouples.

â–  Instrumentation data time synchronised with recorded vehicle network data via CAN.

â–  Galvanic isolation (enclosure, power, CAN BUS and each module of 8 thermocouple inputs).

â–  Stackable ABS enclosure.

â–  Standalone logging capability.

Related Articles

Temperature Data Loggers logo 19.png

 Temperature Management in Automobile

DBC Logo 4.png

Understanding CAN DBC
 

Sleep Mode Logo 5.png

Importance of Wake on CAN and Sleep Modes

Data Logger logo 17.png

Data Loggers and their Importance

Telematics logo 12.png

Telematics and Fleet Management System

Influx_K_Bench white.png
K-Cal, the all in one K-Series instrumentation tool.

K-Cal is freely distributable and supports all K-series modules. 

​

â–  Calibrate sensor channels and output calibration reports

â–  Set CAN Bus baud rate and message identifiers

â–  Set individual signal channel configuration and scaling, using formulas and tables

â–  Set signal sampling rates

â–  Construct, Edit and Export DBC files for CAN bus data

â–  Monitor signals live with a graphical window